Troubleshooting the Serial Converter
5-3
5.1.2 RX Status Indicator
5.1.3 TX Status Indicator
Table 5.2 – RX Status Indicator: State Definitions
State
Cause
Corrective Action
Off
Serial converter is
not receiving data.
• Verify that data is being transmitted.
• Securely connect cables.
• Apply power to the product.
Flashing
Green
Serial converter is
receiving data
from the
computer.
No action.
Table 5.3 – TX Status Indicator: State Definitions
State
Cause
Corrective Action
Off
Serial converter is
not transmitting
data.
• Verify that data is being transmitted.
• Securely connect cables.
• Apply power to the product.
• Configure the computer software to use the
same serial port rate as the serial converter.
Flashing
Green
Serial converter is
transmitting data
to the computer.