Troubleshooting the Serial Converter

5-5

5.3.1 Events

Many events in the Event queue occur under normal operation. If
you encounter unexpected communications problems, the events
may help you or Reliance Electric personnel troubleshoot the
problem. The following events may appear in the event queue:

Table 5.5 – Event Descriptions

Events

Description

Bad Host Flt

The serial converter was connected to an incompatible
product.

Control Disabled

The serial converter has sent a “Soft Control Disable”
command to the DPI product.

Control Enabled

The serial converter has sent a “Soft Control Enable”
command to the DPI product.

DPI Bus Off Flt

A bus-off condition was detected on DPI. This event may
be caused by loose or broken cables or by noise.

DPI Fault Clear

A DPI product has issued a fault clear message.

DPI Fault Msg

The drive entered a faulted state.

Dup. Port Flt

Another peripheral with the same port number is already
in use.

EEPROM Sum Flt The EEPROM in the serial converter is corrupt.

Host Sent Reset

The DPI product issued this because it was reset.

Message Timeout The DPI product did not respond to a message request.

Verify the cables are correct.

No Event

Empty event queue entry.

Normal Startup

Adapter initially powered up or was reset.

Online @
500kbps

The serial converter and DPI product are communicating
at 500kbps.

PCCC I/O Time
Flt

The serial converter has not received a PCCC Control
message for longer than the specified PCCC Control
Time-out.

Ping in Message

An unexpected ping was received.

Ping Time Flt

A ping message was not received on DPI within the
specified time.

Port Change Flt

The DPI port changed.

Port ID Flt

The serial converter is not connected to a correct port on
a DPI product.

Type 0 Login

The serial converter has logged in for type 0 control.

Type 0 Time Flt

The serial converter has not received a type 0 status
message within the specified time.

Use I/O Sent

The serial converter has begun sending product specific
control information.