Linear motor coil – Rockwell Automation LX-Series Iron Core Linear Servo Motors User Manual

Page 37

Advertising
background image

Rockwell Automation Publication LX-UM001A-EN-P - March 2011

37

Wire the LX-Series Linear Motor

Chapter 5

d. For the quick-connect connector, push the connector on and apply a

quarter turn.

e. For the threaded connector, hand-tighten the knurled collar with five to

six turns to fully seat the connector.

Signal and Wire Definitions

for Flying Lead Components

For linear motors, catalog numbers LX

xxxxxxxxxxx0x, wire them by using the

wiring diagram on

page 61

. Wire colors and signal types are shown here; for wire

gauge information see LX-Series Iron Core Linear Servo Motor Technical Data,

publication

LX-TD001

.

Linear Motor Coil

These are the wire colors and signals for the linear motor-coil power and thermal

protection cables, catalog numbers LX

xxxxxxxxxxx0x.

Table 3 - Power Signals

ATTENTION: Be sure that cables are installed and restrained to
prevent uneven tension or flexing at the cable connectors.
Excessive and uneven lateral force at the cable connectors may
result in the connector’s environmental seal opening and closing
as the cable flexes. Failure to observe these safety precautions
could result in damage to the motor or encoder.

ATTENTION: Keyed connectors must be properly aligned and
hand-tightened the recommended number of turns.
Improper alignment is indicated by the need for excessive force,
such as the use of tools, to fully seat connectors.
Connectors must be fully tightened for connector seals to be
effective.
Failure to observe these safety precautions could result in damage
to the motor, cables, and connector components.

Color

Signal

Comments

Red

Motor Phase U (A)

Observe maximum applied voltage specification.

Consult the drive manual or supplier for specific

wiring instructions to the drive. Wiring is phase/
commutation sensitive.

White

Motor Phase V (B)

Black

Motor Phase W (C)

Green

Motor Ground

Terminate per drive manual instructions.

Shield is not connected to the motor frame.

Shield Cable

Shield

ATTENTION: Disconnect the input power supply before installing or
servicing the motor. Motor lead connections can short and cause damage
or injury if not well secured and insulated. Insulate the connections, equal
to or better than the insulation on the supply conductors. Properly ground
the motor per the selected drive manual.

Advertising