Mounting and wiring two identical coils in tandem, Cables exit to the right – Rockwell Automation LX-Series Iron Core Linear Servo Motors User Manual

Page 40

Advertising
background image

40

Rockwell Automation Publication LX-UM001A-EN-P - March 2011

Chapter 5 Wire the LX-Series Linear Motor

Mounting and Wiring Two

Identical Coils in Tandem

This type of installation requires a custom motor-database file, which is available

upon request. Contact Application Engineering at 631.344.6600 to request this

file.

These tables and figures show the wiring and spacing for two identical coils

mechanically top mounted to the same plate and driven by one amplifier. There

are three configurations shown here for mounting motors in tandem: power and

encoder cables exiting on the right, the center, and on opposite ends.

Cables Exit to the Right

If mounting coils in tandem, such that the power cables exit both the coils on

right side, as shown, use the following table to find the mounting distance and the

phase wiring.

Figure 3 - Mounting Two Coils with Cables Exit to the Right

Coils must have identical part numbers. Using mismatched coils
will cause a hazardous condition resulting in damage to the
equipment and a possible fire.

Coil #1

Coil #2

Coil #1 is the master.

Hall Effect
Module

L

Table 6 - Phase Wiring for Right-exit Power Cables

L
mm (in.)

Coil # 1

Master

(1)

Coil # 2

Slave

(2)

Amplifier

Phase

133.33 (5.249)

Red

Red

U

White

White

V

Black

Black

W

(1) Master has Hall effect module.
(2) Slave has no Hall effect module.

Advertising