42

Rockwell Automation Publication LX-UM001A-EN-P - March 2011

Chapter 5 Wire the LX-Series Linear Motor

Cables Exit on Opposite Ends

If mounting coils in tandem such that the power cables exit opposite to each other

as shown, use the following table to find the mounting distance and the phase

wiring.

Figure 5 - Mounting Two Coils with Cables Exit on Opposite Ends

Coil #1

Coil #2

Coil #1 is the master.

Hall Effect
Module

L

Table 8 - Phase Wiring for Opposite End-exit Power Cables

L
mm (in.)

Coil # 1

Master

(1)

Coil # 2

Slave

(2)

Amplifier

Phase

100.00 (3.94)

Red

Red

U

White

Black

V

Black

White

W

133.33 (5.249)

Red

Black

U

White

White

V

Black

Red

W