Cables exit on opposite ends – Rockwell Automation LX-Series Iron Core Linear Servo Motors User Manual
Page 42
Advertising
42
Rockwell Automation Publication LX-UM001A-EN-P - March 2011
Chapter 5 Wire the LX-Series Linear Motor
Cables Exit on Opposite Ends
If mounting coils in tandem such that the power cables exit opposite to each other
as shown, use the following table to find the mounting distance and the phase
wiring.
Figure 5 - Mounting Two Coils with Cables Exit on Opposite Ends
Coil #1
Coil #2
Coil #1 is the master.
Hall Effect
Module
L
Table 8 - Phase Wiring for Opposite End-exit Power Cables
L
mm (in.)
Coil # 1
Master
(1)
Coil # 2
Slave
(2)
Amplifier
Phase
100.00 (3.94)
Red
Red
U
White
Black
V
Black
White
W
133.33 (5.249)
Red
Black
U
White
White
V
Black
Red
W
(1) Master has Hall effect module.
(2) Slave has no Hall effect module.
Advertising