Wire the LX-Series Linear Motor

Chapter 5

Cables Exit in the Center

If mounting coils in tandem, such that the power cables exit in the center as

shown, use the following table to find the mounting distance and the phase

wiring.

Figure 4 - Mounting Two Coils with Cables Exit in the Center

Coil #1

Coil #2

Coil #1 is the master.

Hall Effect
Module

L

Table 7 - Phase Wiring for Center-exit Power Cables

L
mm (in.)

Coil # 1

Master

(1)

Coil # 2

Slave

(2)

Amplifier

Phase

133.33 (5.249)

Red

Black

U

White

White

V

Black

Red

W

(1) Master has Hall effect module.
(2) Slave has no Hall effect module.