Making your own extension cables – Rockwell Automation LX-Series Iron Core Linear Servo Motors User Manual
Page 39

Rockwell Automation Publication LX-UM001A-EN-P - March 2011
39
Wire the LX-Series Linear Motor
Chapter 5
Making Your Own
Extension Cables
Flying lead coil and Hall effect modules require circular DIN-style connectors to
interface with Allen-Bradley extension cables. The following connectors kits are
available for terminating flying lead coils and Hall effect modules.
The cable length from the coil to drive should be limited to 10 m (32.8 ft). If
longer cables are necessary, a 1321-3R
x-x series line reactor is required. Refer to
the 1321 Power Conditioning Products Technical Data, publication
(32.8 ft).
Connector Kit Cat. No.
Application
2090-KFBM7-CAAA
Feedback flex extension cable
2090-KPBM4-12AA
Power flex extension cable
2090-KFBE7-CAAA
Feedback non-flex extension cable
2090-KPBE7-12AA
Power non-flex extension cable