Making your own extension cables – Rockwell Automation LX-Series Iron Core Linear Servo Motors User Manual

Page 39

Advertising
background image

Rockwell Automation Publication LX-UM001A-EN-P - March 2011

39

Wire the LX-Series Linear Motor

Chapter 5

Making Your Own

Extension Cables

Flying lead coil and Hall effect modules require circular DIN-style connectors to

interface with Allen-Bradley extension cables. The following connectors kits are

available for terminating flying lead coils and Hall effect modules.

The cable length from the coil to drive should be limited to 10 m (32.8 ft). If

longer cables are necessary, a 1321-3R

x-x series line reactor is required. Refer to

the 1321 Power Conditioning Products Technical Data, publication

1321-

TD001

, to choose a line reactor for applications requiring cable longer than 10 m

(32.8 ft).

Connector Kit Cat. No.

Application

2090-KFBM7-CAAA

Feedback flex extension cable

2090-KPBM4-12AA

Power flex extension cable

2090-KFBE7-CAAA

Feedback non-flex extension cable

2090-KPBE7-12AA

Power non-flex extension cable

Advertising