Rockwell Automation Publication LX-UM001A-EN-P - March 2011

Appendix A Interconnect Diagrams

Figure 15 - Wiring Example for Kinetix 6000, Kinetix 6500/6200 or Kinetix 2000

Drives and LXxxxxxxxxHxx0x Linear Motor with a TTL Encoder

W

V

U

W
V
U

AM+
AM-

BM+
BM-

IM+
IM-

POWER
COM

4

3

2

1

Green/Yellow

Black

White

Red

GND

W

V

U

TS+
TS -

Black or Red

Black or Red

White

Red

Black

Power
S1
S2
S3
COM

Blue

Orange

1
2

3
4

5

10
14

6

11
12
13

8

Kinetix 2000, Kinetix 6500/

6200 or Kinetix 6000 IAM

(inverter) or

AM Module

Note 3

Motor Power
(MP) Connector

Cable Shield
Clamp
Note 1

Motor Feedback
(MF) Connector
(IAM/AM) Module

Refer to low profile connector
illustration (lower left) for proper
grounding techniques.

Low Profile Connector

TTL Encoder

Turn clamp over to hold
small cables secure.

Clamp

Clamp screw (2)

Ground techniques for
feedback cable shield.

Exposed shield secured
under clamp.

LX-Series Linear Motor Coil

Three-phase
Motor Power

Hall Effect

Module

Wire as shown here using
cable type appropriate for
your application.

Li

ne

ar

E

nco

de

r

Thermal
Switch or
Sensor
Note 3

(Use 2090-K6CK-D15M connector for Kinetix 6000 drives
and 2090-K2CK-D15M connector for Kinetix 2000 drives.)