5.6 Commands

■■■■■■■■■■■■■■■■■■■■■■

1042

■■■■■■■■

tiamo 2.3 (for Process Analysis)

Stirring rate

Setting the stirring rate.

Range

0 ... 15

Default value

3

Switch off automatically

on | off (Default value: on)

If this check box is activated, the stirrer will be switched off automatically
when the command has finished.

5.6.4.14.3

MEAS Opt - Measuring parameters

Tab: Method

MEAS Opt Properties... Measuring parameters

Command name

Name of the command.

Input

25 characters

The parameters for the measuring procedure can be defined on this tab.

Measuring parameters for the Avantes spectrometer

Wavelength

Wavelength at which the measured quantity (absorbance) is recorded.

Range

100.0 ... 2000.0 nm

Default value

400.0 nm

Blank value

Value by which the measured quantity (absorbance) is corrected. Here an
expression can also be entered through the formula editor (e.g. xx.EME
from other measuring command) by which every measured absorbance
value can then be corrected.

Range

-4000 ... 4000 mAU

Default value

0 mAU

Integration time

Integration time for adsorption measurement.

Range

0.01 ... 600000 ms

Default value

6 ms

Averaged spectra

The number of spectra that are recorded and averaged.