5 Method

tiamo 2.3 (for Process Analysis)

■■■■■■■■

1079

5.6.4.19

STDADD auto

5.6.4.19.1

STDADD auto - Overview

Dialog window: Method

STDADD auto Properties... STDADD auto - 'Com-

mand name'

Command for Standard addition with automatic addition of the stand-
ard addition solution from a dosing device in such a way that a constant
potential difference results.

Devices
This command can be executed with the following devices:

Titrando: 808, 809, 835, 836, 857, 904, 905, 906, 907

pH/Ion - Meter: 867

Robotic Titrosampler: 855

Appearance
The command has the following appearance:

Parameters
The parameters for the command STDADD auto are configured on the
following 3 tabs:

General/Hardware
Parameters for devices, dosing devices, sensors and stirrers.

Standard addition
Parameters for standard addition.

Measuring parameters
Parameters for setting the measurement procedure.

Standard addition curve
The standard addition curve with its associated evaluation data for a
determination is shown in the program part Database in the dialog win-
dow Calibration curve, which is opened with the menu item Determi-
nations

Show calibration curve... or the symbol .

Command variables
The following command variables are generated in the method run by the
command STDADD auto and can be used in formulas under the desig-
nation 'Command name.Variable designation':