A.6 system setup & diagnostic menus, Icnc xt – Tweco iCNC XT User Manual

Page 104

Advertising
background image

iCNC XT

A-6

APPENDIX

Manual 0-5299

A.6 System Setup & Diagnostic Menus

Advanced Tab

Provides the option for more detailed control of the system behavior.

Default Values

Imperial

Metric

High Jog Speed

59,06 IPM

1500 mm/min

Low Jog Speed

11,81 IPM

300 mm/min

Adjust Speed

118,11 IPM

3000 mm/min

Homing Speed

23,62 IPM

600 mm/min

Find Plate Speed

23,62 IPM

600 mm/min

Plate Contact Release Speed

2,36 IPM

60 mm/min

Main Arc Lost Time Out

1 s

Hold Off AVC Delay

0.0 s

Collision Retract Height

0.4”

1mm

Collision Recovery Delay

1 s

Plate sensing force

25

Max allowed force

250

• Collision retract enable Enables the collision retract feature that lifts the torch when plate contact has occurred while cutting. This feature

is mainly used to protect torch consumables from hot slag emerging on top of the plate after piercing. Higher pierce height must be used

to protect consumables while piercing. If Collision Rectract activates all the time while cutting, check system for proper cutting speed,

arc voltage and gas pressure.

• Collision retract height Sets the height the torch retracts to after plate contact has occurred while cutting is active
• Collision recovery delay Determines how long the torch will remain in the collision retract height until automatic height control is activated

again

• Ohmic plate contact enable. Using this function requires a connection between the torch shield cap and the voltage divider. This method

is more accurate and sensitive than the Plate sensing by force. Ohmic plate contact should always be used as the main plate sensing

feature if possible. This function is not usable when cutting under water.

Advertising