Section 2: specifications, Section 2: specifications -1, Icnc xt – Tweco iCNC XT User Manual
Page 17
iCNC XT
Manual 0-5299
SPECIFICATIONS
2-1
SECTION 2: SPECIFICATIONS
XT2
XT211
XT231
XT242
Processor
2, Intel (secondary processor for motion & I/O)
Operating system
XPE
Ram
2GB
Ethernet ports
1 Rj-45
USB ports
3, 2 On backwall (USB2.0) + 1 On door (USB2.0)
Serial ports
2 RS-422/485 ports on d-sub 9 pin
Hard drive
80GB SATA SSD
Operating console
Total of 5 switches (does
not have laser pointer
switch)
Total of 17 switches
(includes laser pointer
switch)
Total of 23 switches
(includes laser pointer
switch)
Total of 22 switches
(does not have laser
pointer switch)
Display
15” With touch panel (resistive)
Configuration
1 Plasma
1 Plasma, 1 oxy, 1 pow-
der marker
1 Plasma, 3 oxy, 1 pow-
der marker
2 Plasma, 4 oxy, 1
marker
Number of I/O
7 Relay outputs, 6 inputs 27 Relay outputs, 8 in-
puts
51 Relay outputs, 8 in-
puts
52 Relay outputs, 2x5
inputs
I/O type
Line voltage / potential
free outputs
Line voltage or user voltage / potential free outputs Line voltage / potential
free outputs
Axes available
2-3 Y, 1 X, optional 1 iHC Z
Default drives interface
Analog +-9V speed signal, incremental encoder inputs
Integrated drives
Optional 400W / 750W integrated Yaskawa drives
Integrated plasma height control
Optional iHC height control (for up 2 torches)
CNC AC input power volts (amps) 115VAC/230VAC (10A) (without drives 115VAC 3A, 230VAC 1.5A. With drives 115VAC 3A, 230V 10A.)
Drive AC input power volts (amps)
230 VAC (10A)
Cnc protection device
10A slow blow fuse
Optional IO Expander Card with 16 relay outputs available for all iCNC XT models (down draft control)
On XT2 and XT242 all voltage outputs share the same inlet voltage level. There is no inlet for external voltage supply. If internal inlet cable is
removed, external voltage for relay outputs can be connected to line & neutral pins. However, even then all voltage output relays share the same
voltage level (outputs for gas solenoids, lifters etc.
On XT231 and XT211 as a default gas solenoid outputs are configured for inlet voltage output. On output connectectors there are pins for user
voltage that can be used instead if couple of relays are moved on relay card. It is also possible to use different voltage levels for gas solenoids
and gas torch lifter outputs. XT211 and XT231 directly support both ac and dc lifters and common capacitive height controls.