Procedure

During initial power up, the iCNC® XT may display a Start homing procedure dialog box. If you select Yes, the machine will automatically locate
the absolute zero home location. As a default, this is normally set at the bottom left corner of the cutting table, however this is selectable in the
set-up parameters. If you select No, the dialog box disappears and no movement is executed.

5.9.1. Plate Alignment

Activating Plate Alignment allows for a quick and easy way to pick two points on the edge of a skewed plate. Performing this exercise will
automatically rotate a part or program nest the same amount as the plate skew so that it will fi t precisely onto the plate, reducing scrap or
manual plate squaring.

To use the Plate Alignment feature, locate a corner or plate edge and click Set point 1 here. Select which direction the next point is relative to the
fi rst location, travel to the second point and click on Confi rm point 2 here. This will automatically rotate the program to match the skewed plate