iCNC XT

Manual 0-5299

APPENDIX

A-7

• Plate sensing force enabled activates motor current based plate recognition. When enabled Plate sensing force is used to recognize a

plate. This feature can be used together with ohmic plate contact as a backup for the ohmic contact, or it can be used as primary plate

sensing feature: ie cutting under water

• Plate sensing force Sets the contact force, range 1-190. Increasing the value will cause a plate to bend under pressure and makes plate

sensing more inaccurate (in case ohmic sensing is not active)

• Max allowed force Sets the maximum allowed force used to drive the lifter, range 1-1000. This value is also used when Plate sensing

force is disabled.

• MAX window Real time values of the maximum forces to the lifter
• Drive force Real time value of applied force to the lifter
• Reset Resets the max values

A.7 I/O Bits Tab

This tab displays the status of various system signals for diagnostic purposes. I/O bits are separated to inputs (signals that come from other

devices to iHC) and outputs (signals that go from the iHC to other devices).

• I/O bits are also separated to general I/O bits, lifter I/O bits, servo I/O bits.
• If the system has two torches both lifters and servos have their own I/O bits.

General

Input

1. Hold - AVC turns off when Hold inbit turns active. Hold is used during cutting to prevent the torch from diving to the plate when move-

ment slows down ie: during tight corner.

2. Torch Collision - In case lifter has a breakaway/collision sensor, signals from the sensor can be wired into Torch Collision input. Torch

Collision will activate System Error output to CNC

3. Maintain ARCV - Inbit used with bevel head cutting.

4. Spare - Reserved for future use

Output

5. Main Arc - Outbit to CNC which becomes active when the main arc inbit is activated and the transfer delay has passed.

6. IHS Ready - Outbit becomes active when the lifter reaches the Ignition Height.

7. System Error (Inverted) – Can be connected to CNC controllers external stop

8. Sense Relay – 24Vdc Output for voltage divider board.