7 xt211/231 switch description and functions, Xt211/231 switch description and functions -19, Icnc xt – Tweco iCNC XT User Manual

Page 77

Advertising
background image

iCNC

XT

Manual 0-5299

OPERATION

5-19

5.7 XT211/231 Switch Description and Functions

5.7.1 Station Select Switches

NOTE:

Switches Not available in XT211 (See blue box on the picture above)

Station Select Switches 1 – 3.

With the STATION SELECT switches the operator can select which Oxy Fuel torches are in use.

The switches have 2 positions: Up/On, Down/Off

OFF for Oxy-Fuel stations 1 – 3:

• A station is not selected

• Preheat gases, cutting oxygen, water spray, ignition and pierce signals are disabled for this torch

• Torch Up and Down switches for this torch are disabled

• All Up / Down switch does not effect this torch

ON for Oxy Fuel stations 1-3 means that:

• Torch Up and Down switches for this torch are enabled

Preheat gases, cutting oxygen, water spray and ignition are disabled for this torch

• All Up / Down switch will drive this torch

Main gas signal will always activate even when all station select switches are Off.

Advertising