ULTRA-CUT 400 XT

5-2

MAINTENANCE

Manual 0-5306

CAUTION

Applying more than 5 psi air pressure to the cooling system will result in damage. Extra caution must be used when

performing this task.

2

1

Art # A11689

5. Reconnect those two fittings and then remove the filter bowl from the canister at the rear of the power supply. Pour this

remaining coolant into the container and replace the filter bowl.

NOTE

If you also need to replace the coolant still in the leads, disconnect the leads from the power supply and manually

drain them.

6. Fill the tank with fresh coolant until the right level is reached checking for leaks.

7. Turn system on, let it run for a few minutes and check coolant level, refill as needed. Refer to Section 3:23 Complete the

Installation on the procedure for this.

8. Install the side panels.