Ultra-cut 400 xt, Caution – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual

Page 36

Advertising
background image

ULTRA-CUT 400 XT

3-14

INSTALLATION

Manual 0-5306

3.12 Connect TSC-3000 Cable and DMC-3000 Fiber Optic Cable to CCM

1. Remove the bottom plastic plug in the CCM at the rear of the Power Supply.

COOLANT

RETURN SUPPLY

Art # A-11991

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

TSC-3000 Cable

DMC-3000 Fiber

Optic Cable

CAUTION

Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into tight-radius

turns.

2. Remove outer thin nut from through hole protector at one end of Fiber Optic Cable (L) that connects between the CCM

portion of the Power Supply and the DMC-3000.

3. Feed the Fiber Optic Cable plug and wires through the hole where the plastic plug was removed labeled GCM/DMC and

slide the thin nut back over the Fiber Optic Cable.

4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside and out.

5. Plug the Fiber Optic Cable into the PCB as shown below. Make sure the locking tabs are engaged. Fiber Optic for the

DMC-3000 goes into the lower pair of fiber optic receptacles (U31 & U37).