ULTRA-CUT 400 XT
3-12
INSTALLATION
Manual 0-5306
Art # A-09677_AB
Hose not secured in
the Strain Relief
Correct installation:
Correct way to pull the cable is to use a snake or a wire or another cable and attach it securely to the hose behind the strain relief.
Then secure the fiber connector to the pulling device leaving some slack in the fiber. Keep the protective end covers on the fiber
until you are ready to connect it to the PCB in the CCM or gas control.
Art # A-09420
Correct installation in CCM or Gas Control leaves a loop of fiber so there is no stress on the fiber where it exits the connector or
the hose.
Art # A-12014
No
sharp
bends
CCM
No
Sharp
Bends