ULTRA-CUT 400 XT

A-48

APPENDIX

Manual 0-5306

External or CNC Plasma Enable D2, CNC PLASMA ENABLE LED, is not on.

• LED D2 on the CCM will be on if this input is satisfied either with the jumper on TB1- 1 & 2 or an external or CNC

switch. If the jumper is in place and the LED is not on, the CCM is most likely defective.

• If the jumper at CCM TB1-1 & 2 has been removed to use an external switch, install a jumper as a test. If D2 illuminates

the problem is with the switch or it’s wiring.

• If Plasma Enable is wired through the CNC cable remove the cable and jumper J15 pins 25 & 26. If D2 still not on

there may be a problem in the wiring inside the power supply.

Plasma Enable from Gas Control or TSC 3000

If the External or CNC Plasma Enable is satisfied, D2 is on, a relay K7 on the CCM I/O PCB energizes supplying +15V to

another relay K1 on the I/O board. An active low signal, /Plasma Enable-HMI, comes from TSC 3000 Plasma Enable switch

via the Relay PCB or if TSC 3000 is not installed the signal originates on the Relay PCB. This signal applies ground to the K1

relay energizing it and lighting the LED, D3 on the I/O board. K1’s contacts go back to the Relay board and the Gas control

connector J55 to allow turning on relays and solenoids on those devices. The AC 200 XT does not use the separate Gas

Control or the TSC 3000.

Art # 12304

1

5

3

2

4

K7

1

8

4

2

6

7

3

5

PLASMA ENABLE

K1

/PLASMA ENABLE - HMI

GND

24 VAC

24 VAC

TSC 3000

RELAY PCB

1

5

3

2

4

PLASMA ENABLE - CNC

K6

+15VDC

GREEN

D3

PS_ENABLE

To

Relay

PCB

To Gas

Control

CCM I/O PCB

GREEN

D2

Plasma Enable SW

GCM 2010

(or jumper in

other gas controls)

-1
-3

-5

-6

J54

J55

XT Power Supply

Simplified schematic, all connectors are not shown.

Refer to unit schematics for details.

J61

J56

-1
-2

Jumper in

AC 200 XT

J26-6
J26-7

GCM 1000 XT

J56

J54

When the circuit between J54-1 & 3 is closed (jumper,

etc.) K7 is energized and requires a Plasma Enable SW

or equivlant to enable the plasma.

With J54-1 & 3 open K7 is denergized and it's NC

contacts complete the Plasma Enable-HMI circuit.

-1
-2

-2

-1

-5

-6

-3

-1

-5

-6

-3

-1

(AC 300 XT

DMC 3000)

J25

-15

-22

J30

-20

-25

Plasma

Enable

SW

iCNC

XT 2 &

XT 242

J54

-5

-6

-3

-1

iCNC

XT 211

HMI PLASMA

ENABLE BYPASS

If a TSC 3000 is not connected or unit is an Auto-Cut, K7 on the Relay PCB is de-energized and GND is connected through

its normally closed contacts. If the TSC is connected, 24 VAC through a jumper in the TSC 3000 energizes K7, opening its

NC contacts and now GND connects through the TDC 3000 Plasma Enable switch. The GND obtained by either path passes

through the GCM 2010 Plasma Enable switch or through a jumper (J56-1 to J56-2) present in the other gas controls (GCM

1000 XT or DMC 3000) and is connected to the coil of K1 on the I/O PCB. If the CNC Plasma Enable is also active (D2 is

on) +15V will be connected to K1’s coil through the relay K7 on the I/O PCB. This energizes K1 and turns on D3, Plasma

Enable LED. The contacts of K1 go back to the Relay board and to the Gas control to enable power to connect to relays and

solenoids in those items.

Troubleshooting:

1. If both D2 and D3 are on and you still have 101 fault replace the CCM. Otherwise go to step 2 except if it’s an AC 200

XT skip to step 4.

2. If D3 is not on and there is a TSC 3000 in use remove its cable from J54. K7 on the Relay board will de-energize and

satisfy the Plasma Enable to K1. If D3 is now on problem was in the TSC 3000 or its cable. Otherwise reconnect the

cable.

3. For an Ultra-Cut with DFC 3000 or GCM 2010 or an Auto-Cut 300 with a GCM 1000 XT remove the cable from J55

the gas control connector and jumper pins 1 & 2. If D3 is on now problem is in the Gas Control or its cable. If D3

still not on replace the Gas Control cable.

4. If neither of the above steps works, on the CCM I/O board, jumper J26-7 to GND (TP1 on I/O). If D2 is on and D3

still does not light then replace the CCM.