06 specifications & electrical requirements, Specifications & electrical requirements -2, Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual

Page 16

Advertising
background image

ULTRA-CUT 400 XT

2-2

SPECIFICATIONS

Manual 0-5306

2.06 Specifications & Electrical Requirements

400 Amp System

Ultra-Cut 400 XT™ Specifications & Design Features

Max OCV (U0)

425 vdc

Minimum Output Current

5 Amps

Max Output Current

400 Amps

Output Voltage

60 - 200 vdc

Duty Cycle Rating

100% @ 400A, 200V, (80kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 400 A DC Output

Cooling

Coolant and Forced Air (Class F)

Ultra-Cut 400 XT™ Power Supply

Input

Power Input Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG) Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

480

50/60

93

114

175

#3

35

NOTE

* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the

National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord of certain types rated for

75 deg C in ambient temperatures up to 30 deg C. Using wires of lower temperature rating or different insulation

type may require larger wire size. De rate for higher ambient.

These are suggestions only. Always refer to your local and national codes that apply to your region for final deter-

mination of correct wire type and size.

Advertising