ULTRA-CUT 400 XT

Manual 0-5306

INSTALLATION

3-37

3. The Arc Starter must be grounded; the grounding terminal is marked . Refer to the previous section for grounding

details.

Ground Cable

Art # A-04758

1 Nut and 1 Washer
Remain in Place

Torch Leads

4. Use a clamp to secure the Torch Lead Shield braid brass ring to the port on the Remote Arc Starter as shown.

Art # A-04759

Coolant and Pilot Leads
to Torch Valve Assembly

Torch Leads Shield

Shield Clamp