ULTRA-CUT 400 XT
Manual 0-5306
INSTALLATION
3-29
Fiber Optic Cable to/from
CCM plugs in here
Art # A-11999
3.19 Fiber Optic Cable Installation From DMC-3000 to DPC-3000
1.
Remove outer thin nuts from through hole protector at both ends of Fiber Optic Cable (L) that connects between the
DCM-3000 and DPC-3000.
CAUTION
Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into tight-radius
turns.
2. Ensure that the outer protective hose/cable is exposed beyond the through hole protector approximately 1” and secure by
tightening the wide nut with the rounded end while holding the other nut in place. Normal hand tightening is not enough.
3. Feed the Fiber Optic Cable plug and wires through the back of each module (DMC-DPC) where indicated and slide the
thin nut back over the Fiber Optic Cable.
Fiber Optic for
DMC-3000 goes here
Art # A-09152_AB