25 complete the installation, Complete the installation -45, Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 67

ULTRA-CUT 400 XT
Manual 0-5306
INSTALLATION
3-45
3.25 Complete the Installation
1. Remove the cap from the coolant tank. Fill the coolant tank to the level shown, with Thermal Dynamics coolant. The
coolant level is visible through the translucent coolant tank. The amount of coolant required varies with torch leads length.
Coolant Capabilities
Cat. Number and Mixture
Mixture
Protects To
7-3580 ‘Extra-CoolTM’
25 / 75
10° F / -12° C
7-3581 ‘Ultra-CoolTM’
50 / 50
27° F / -33° C
7-3582 ‘Extreme CoolTM’
Concentrate*
-65° F / -51° C
* For mixing with D-I CoolTM 7-3583
Art # A-11536
Fill Range
Coolant Tank
2. After the complete system has been installed, check that the coolant has been pumped through the system as follows
(see NOTE):
NOTE
Depending on the length of the torch leads, the system may require more coolant after turning the system
ON for the first time.