ULTRA-CUT 400 XT

4-26

OPERATION

Manual 0-5306

Group 3 - CCM Communication Port *

3-1

CCM Acknowledge error

Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;

Replace DMC Control PCB; Replace CCM.

3-2

CCM Bus off error

Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;

Replace DMC Control PCB; Replace CCM.

3-3

Reserved

No information available; Contact customer service

Group 4 - Gas Controller Status and Protocal Errors

4-1

CCM Connection loss

Loss of communication with either DPC or DMC; check for dirty or defective fiber optic

to either DPC or CCM; See DPC and CCM status codes

4-2

CCM Timeout

Loss of communication with either DPC or DMC, check for dirty or defective fiber-optic

to either DPC or CCM. See DPC and CCM status codes.

4-3

DPC Timeout

Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See

DPC status code.

4-4

DPC error

Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See

DPC status code.

4-5

Reserved

No information available; Contact customer service

4-6

Reserved

No information available; Contact customer service

Group 5 - Shorted Solenoid Faults

5-1

Sol 1 – H35 Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-2

Sol 2 – Oxygen Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-3

Sol 3 – Air Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-4

Sol 4 – Nitrogen Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-5

Sol 5 – Aux Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-6

Sol 6 – Oxygen Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-7

Sol 7 – Air Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-8

Sol 8 – Nitrogen Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-9

Sol 9 – H2O Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-10

Sol 10 – Oxygen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-11

Sol 11 – Air Preflow

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-12

Sol 12 – Nitrogen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-13

Sol 13 – Argon Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-14

Sol 14 – Air Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-15

Sol 15 – Nitrogen Mark-

ing

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

* Communication faults shown on the DMC can be caused by the device on the other end of the communication line.

Before assuming the DMC is at fault see if either the CCM or the DPC are showing any codes that might indicate they are at

fault instead.