Ultra-cut 400 xt, Mc2a mc2b, Fan1 – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual

Page 195

Advertising
background image

ULTRA-CUT 400 XT

Manual 0-5306

APPENDIX

A-71

403

Coolant overheated.

TS1 is a linear negative temperature coefficient (NTC) resistor sensor attached to the brass fitting at the exit of the bypass

valve. Here we determine the coolant being supplied to the torch is below the required temperature which is currently 75

deg C (167F). The radiator is on the lower right side of the unit. The fan(s) are behind it and blow out through the radiator.

100A & 200A units may either have 2 smaller fans or one larger one. The 300 & 400A units have one larger one.

Fans operate during cutting and for 4 minutes after last cut then shut off. Exception is AC 200 XT where the fans are on

whenever power is on. The external heat exchanger, HE400, fan is thermostatically controlled so it only comes on when

coolant is over 60 deg C. It will shut off when the other fans shut off.

Possible reasons for coolant overheated:

Coolant fan(s) failed or defective fan control relay MC2.

• Radiator fins clogged with dirt.
• Duty cycle exceeded (ambient temperature above 40 deg C and operating at high duty cycle).
• Operating with an object placed in close proximity to the air outlet (right side of the unit) or the front panel inlet open-

ings.

• Operating for extended time with right lower side panel removed.
• Defective Relay board.
• Defective CCM.

Troubleshooting:

1. Check for air blowing out of the unit. Remember, except for the AC 200 XT, the fans only run when CNC START is applied

and for 4 minutes after cutting, you may have to apply start again to restart the 4 minute time. Fans may be forced on

by jumping TP2 on the CCM I/O board to TP1 (ground).

a. If using the external HE400XT heat exchanger, optional for 300A, standard for 400A, check for air blowing out of it.

Note that the HE400XT fan, controlled by a thermal switch in the HE400XT, only runs if the coolant is over 60 deg

C and the internal fans are operating. With the 100 & 200A if it has 2 fans make sure both fans are operating by

checking for air both top and bottom of the opening. The fans are difficult to see, perhaps you can use an inspection

mirror. Be careful not to get the mirror or your hands into the blades.

2. Fans are powered by 230 VAC. The 230 VAC for the fan(s) is switched by the MC2 control relay (except the AC 200 XT

where the fan(s) is powered directly from the T1 transformer at J13).

Art # 12311

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

J8

1

5

3

2

4

Fan Bias Control

K4

MC2

Fan Control

(160)

(161)

SA3

ARC_SUPPRESSOR

D24

24 VAC

Relay PCB

230 VAC from T1

MC2A

MC2B

To J70-2

To J70-3

(69)

(70)

(70)

(65A)

(70)

(69)

1

2

3

J73

(64A)

CHASSIS GND

1

2

3

J72

C4

FAN1

R

R

BK

BN

BL

1

2

3

4

J13

TP1

TP2

CCM I/O PCB

To test fan relay jump TP2 to TP1.

+24

J4-19

3. Check for 230 VAC at either of the fan connectors, J72 & J73. It may also be measured at the rear panel connector J70

for the HE400XT fan.

a. If the fans are not getting 230 VAC, measure for 24 VAC on the coil of MC2. If present and the relay contacts aren’t

closed the relay is defective. Note, the coil is rectified so you won’t measure continuity of even a good coil.