OPERATION

4-21

CCM Status Code

Group 2 -- Plasma Power Supply

Code

Message

Remedy / Comments

256

Inverter 2B Over Temp

Inverter Module 2 Section B is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

257

Inverter 3A Over Temp

Inverter Module 3 Section A is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

258

Inverter 3B Over Temp

Inverter Module 3 Section B is over temperature; Operating with side panels re-

moved, Check for restricted air flow, clogged radiator; Defective fan; If problem

persists replace inverter module.

259

Inverter 1A Over Temp

Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg

C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add

auxiliary cooler.

260

Inverter 1B Over Temp

Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg

C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add

auxiliary cooler.

261

Inverter 2A Over Temp

Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg

C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add

auxiliary cooler.

262

Inverter 2B Over Temp

Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg

C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add

auxiliary cooler.

263

Inverter 3A Over Temp

Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg

C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add

auxiliary cooler.

264

Inverter 3B Over Temp

Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg

C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add

auxiliary cooler.

265

Inverter 1A No Input

Power

Inverter section may have no input power. Contactor W1 not closed; Defective con-

tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.

266

Inverter 1B No Input

Power

Inverter section may have no input power. Contactor W1 not closed; Defective con-

tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.

267

Inverter 2A No Input

Power

Inverter section may have no input power. Contactor W1 not closed; Defective con-

tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.

268

Inverter 2B No Input

Power

Inverter section may have no input power. Contactor W2 not closed; Defective con-

tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.

269

Inverter 3A No Input

Power

Inverter section may have no input power. Contactor W2 not closed; Defective con-

tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.

270

Inverter 3B No Input

Power

Inverter section may have no input power. Contactor W2 not closed; Defective con-

tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.

271

Inverter ID reading

fault

CCM found ID values inconsistant during reading. CCM to an Inverter section rib-

bon damaged or disconnected; Inproper ribbon cable routing.