Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 39

ULTRA-CUT 400 XT
Manual 0-5306
INSTALLATION
3-17
SW-6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)
SW-11: Set “B” position, (up) for default
SW-11: Set “A” position (down) for remote analog current control. SW-8-2 must be set to “ON”.
SW-12-1/2/3/4: Divided Arc signal All = OFF = 50:1 (Factory default setting)
1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = ON = 25:1
Art # A-12016_AB
Only 1 on at a time.
SW13: Ultra-Cut Switch positions
SW13
SW6
SW12
SW13 (Note positions 3-4 are not yet used)
1
2
3
4
ON
SW11
2 - Wire and 4 - Wire settings
When used with the TSC-3000 the plug should be in the 2 wire (2W) position shown below.
For other CNC controls using 4 wire communication such as the XT iCNC, place the jumper in the 4W position.