Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 55

ULTRA-CUT 400 XT
Manual 0-5306
INSTALLATION
3-33
Installation
The Remote Arc Starter must be installed in a suitable location near the torch head.
If the Arc Starter is mounted to a gantry or
to any other support subject to motion or vibration, fasten the Arc Starter to the support securely.
1. Loosen, but do not remove, the lower screws securing the cover to the Arc Starter. Remove the upper screws securing
the Cover Panel to the Arc Starter.
NOTE
A ground wire connects the cover to the Arc Starter base. This wire must remain in place.
2. Remove the Cover Panel from the Arc Starter.
Art # A-12059
Lower screws
(2 per side)
Upper screws (2 per side)
Cover
Ground Wire
Cover Removal
3. Position the Arc Starter on a flat, horizontal mounting surface.
4. Use pre-drilled holes in at least two of the feet on the bottom of the Arc Starter to secure the Arc Starter to the mounting
surface.
Art # A-12060
Minimum 2