4.08 Back up and Restoration of Custom Processes

Users can create their own custom cut processes. These can be lost by accidentally deleting them on the TDC 3000 or they can

be over written when updating programs. They can also be lost if the DSC 3000 should be replaced. We recommend you back

up your custom processes every time a new one is created. To back up you will need a USB Flash drive.

Backing Up Custom Process:

1. For the remotely mounted DSC 3000 insert the flash drive in the USB connector on the back. If using the TSC 3000 mounted

in the plasma supply front panel the USB connector is in the front under the clear plastic protective screen.

2. Go to the HOME screen. Select SETUP. Enter the 5 digit password (00000) unless you’ve changed it.

3. Press button “Back Up Custom>USB”

4. Very quickly, depending on how many custom processes there are, you should see along the bottom of the screen the mes-

sage “Copy to D:\TD\CustomFiles\Complete” at which point you can remove the flash drive.