Trouble Conditions and Corrective Actions
Fault Condition
Fault
Corrective Action
Blink Amber trouble LED
using repeating Blink *1
pattern.
*A 1 second blink with a 5
second pause.
Input power under
16VDC**
Correct input voltage to 24VDC (nominal);
(operates from 16-33VDC)
Blink Amber trouble LED
using repeating Blink 2*
pattern.
*Two 1 second blinks with a
5 second pause.
Laser over current
condition**
Replace Beacon Insert Assembly
Blink Amber trouble LED
using repeating Blink 3*
pattern.
*Three 1 second blinks with
a 5 second pause.
Motor over current
condition**
Replace Beacon Insert Assembly
Blink Amber trouble LED
using repeating Blink 4*
pattern.
*Four 1 second blinks with
a 5 second pause.
Invalid DIP switch
configuration
All DIP switches are OFF**
Refer to DIP Switch Setting/Configuration
Section II.4 for valid switch selections.
Blink Amber trouble LED
using repeating Blink 5*
pattern.
*Five 1 second blinks with a
5 second pause.
Key switch stuck error**
If key switch is detected as
turned for >= 30 seconds.
Inspect operation of cylinder cam with
Beacon plastic switch actuator.
Free possible obstruction or replace
Beacon Insert Assembly if inoperable.
**
Disables all audible and visual notification alerts.