Beacon Exit Device
Installation and Wiring Instructions
FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com
SECTION II: Installation Instructions
Rail assembly is shipped with cylinder installed.
A. If cylinder does not need to be replaced, verify proper switch settings for
your facility in
Section II.4 - Alarm Mode Operation/Dip Switch Settings
and Section II.5 - Alarm Notification Switch Setting (NAC/CC).
B. If replacing cylinder, go to
Section II.3 - Cylinder Installation/Replacement.
C.
Complete wiring connections - refer to this manual’s example
wiring diagrams (
Section III) for proper connections.
D. Refer to 80 Series installation instructions and complete
exit device installation.
End Cap
Mounting Bracket
Fig. 4
1. New Installation
If installing new Beacon insert assembly on
existing mechanical rail:
A. Remove end cap and mounting bracket from rail assembly.
B. Remove insert plate by sliding out from rail assembly.
C. If replacing cylinder, go to
Section II.3 - Cylinder Installation/Replacement.
D. Slide Beacon insert assembly into rail assembly (Fig. 5).
E. Complete wiring connections - refer to
this manual’s example wiring diagrams in
Section III for proper connections.
F. Reinstall mounting bracket and end cap.
2. Kit Installation - Replacement/Servicing
Fig. 5
Rail Assembly
Beacon Insert Assembly