8 A7974C
Beacon Exit Device
Installation and Wiring Instructions
FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com
Cam rotates to
engage actuator
Cylinder & Collar
Nut
Beacon
Insert Assembly
Fig. 8
Fig. 9
Plastic Switch Actuator
3. Cylinder Installation/Replacement
To install or replace cylinder, Beacon insert assembly
must be removed from exit device.
NOTE: Remove power from device.
A. If necessary, remove end cap and mounting bracket.
B. Slowly slide insert assembly (partially) away from push
bar (Fig. 7), carefully checking for any additional wires
required for TL- prefix.
NOTE: Disconnect all wiring connectors before
attempting to fully remove insert assembly.
NOTE: Use factory-supplied rings and collars.
F. Install cylinder with cylinder cam in proper
position. Cam must be positioned so that it makes
solid contact with plastic switch actuator when
rotated (Fig. 9).
Note: Cylinder must be installed as shown for
proper switch operation.
G. Complete wiring connections - refer to this
manual’s example wiring diagrams in
Section III
for making the proper connections.
H. Install mounting bracket and end cap.
I. Refer to 80 Series installation instructions and
complete exit device installation.
C. Remove insert assembly from exit device.
D. Rotate cylinder nut counter clockwise and remove (Fig. 8).
E. Remove cylinder and collar (Fig. 8).