Beacon Exit Device

Installation and Wiring Instructions

FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com

Total

One-Way

Length of

Wire Run (ft)

Load Current @ 24VDC

1/4A

1/2A

3/4A

*1A

1-1/4A

1-1/2A

2A

3A

100

24

20

18

18

16

16

14

12

150

22

18

16

16

14

14

12

10

200

20

18

16

14

14

12

12

10

250

18

16

14

14

12

12

12

10

300

18

16

14

12

12

12

10

400

18

14

12

12

10

10

500

16

14

12

10

10

750

14

12

10

10

1,000

14

10

10

1,500

12

10

4. Wire Gauge Chart

*When calculating voltage drop, use 1A as the
recommended current draw for the BEACON

• Accepts alarm signal from either dry contact relay or 24VDC from the Notification Appliance Circuit

(

NAC) of a Fire Alarm Control Panel (FACP)

• Low current draw 30mA @ 24VDC in Standby Mode, 900mA max @24VDC in Alarm Mode ensures long

operation time on back-up batteries. Power supply required; 24VDC, 1.0 amp, filtered and regulated.
• Test mode and diagnostic trouble reporting for ease of installation and periodic functional checks
• Customizable functionality through on-board adjustment of dip switch and NAC/CC slide switch settings
• Centralized control from fire alarm control panel (FACP) with silence and reset commands
• AHJ (Authority Having Jurisdiction) needs to authorize setup

3. Electrical Specifications

IMPORTANT: ElectroLynx connectors plug and

lock together in only one way.

Do NOT force connectors together.

Fig. 3 ElectroLynx Connections

Locking Mechanism

Receptacle

Plug

5. ElectroLynx Wiring System

Caution:

1. Disconnect all input power before beginning installation to prevent electrical shock and

equipment damage.

2. Installer must be a trained, qualified service person.

3. All wiring must comply with applicable local electrical codes, ordinances and regulations.

4. Beacon is equipped with a Class IIIa 5mW max output power (Green) laser.

Warning: Do NOT stare into laser beam.

BEACON exit devices are supplied with one 4-pin and one

8-pin Molex® connector harness, allowing simple installation

using the ASSA ABLOY ElectroLynx® system.

NOTE: For wire locations and positions, see

wiring examples later in this document.