Touchlinx, Touchlinx -79 – ClearOne NetStreams DigiLinX Dealer User Manual

Page 149

Advertising
background image

Editing Devices

5-79

All specifications subject to change without notification. All rights reserved. Copyright © 2008 NetStreams

Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496

3600 W. Parmer Lane, Suite 100; Austin, TX 78727 /

www.netstreams.com.

The IR tab allows you to configure how DigiLinX responds when it receives a source or macro IR command.
By default, KeyLinX and IRLinX are configured to allow IR to pass through the network to the currently
selected source. Network IR passthrough must be disabled if you do not want IR to pass from the selected
IRLinX or KeyLinX. You can configure source and macro assignment. Table 5-51 provides information on
the fields available for editing the IR/KeyLinX tab.

11.

After adjusting information on the IR page, select Apply.

TouchLinX

To edit TouchLinX settings, complete the following steps:

1.

Click on the TouchLinX you want to edit in the project.

The Info tab for the TouchLinX displays in the right side of the window (see

Figure 5-63).

Figure 5-66

TouchLinX Info tab

The Info tab contains all of the information for the designated TouchLinX. You can write comments in the
comments field to indicate where the device is installed in the building. If you ever need to return to the

Table 5-51

IR Tab

Tab

Selection Description

IR

Enable IR Network Pasthrough

Enables IR network passthrough for IRLinX.

Source <#>

Sets the device for DigiLinX to select when it receives the
source IR command.

User <#>

Enables the macro selected when DigiLinX receives an IR
macro command.