Troubleshooting

131

9

Troubleshooting

To get help with your Dell PowerEdge RAID Controller (PERC) H700 and

H800 cards, you can contact your Dell Technical Service representative or

access support.dell.com.

Post Error Messages

The controller BIOS read-only memory (ROM) provides Int 13h functionality

(disk I/O) for the virtual disks connected to the controller. You can boot from

or access the physical disks without a driver. Table 9-1 describes the error and

warning messages for the BIOS.

Table 9-1. BIOS Errors and Warnings

Error Message

Probable Cause

Corrective Action

A discovery error has
occurred, please power
cycle the system and
all the enclosures
attached to this
system

The message indicates that

discovery did not complete

within 120 seconds. The

SAS cables for your system

might be improperly

connected.

Check the cable

connections and restart

the system.

There are X enclosures
connected to connector
Y, but only maximum of
4 enclosures can be
connected to a single
SAS connector. Please
remove the extra
enclosures then
restart your system.

This message is displayed

when the BIOS detects

more than 4 enclosures

connected to a single SAS

connector.

Remove all additional

enclosures and restart

your system.

PERC7.2_UG.book Page 131 Thursday, March 3, 2011 2:14 PM