Dell PowerEdge RAID Controller H700 User Manual

Page 138

Advertising
background image

138

Troubleshooting

The foreign
configuration message
is present during POST
but no foreign
configurations are
present in the foreign
view page in CTRL+R.
All virtual disks are
in an optimal state.

Ensure all your Physical

Disks (PD) are present

and all virtual disks are

in optimal state. Clear

the foreign

configuration using

<Ctrl><R>

or Dell

OpenManage Server

Administrator Storage

Management.

CAUTION:

The

physical disk goes to
Ready state when you
clear the foreign
configuration.
If you insert a physical

disk that was previously

a member of a virtual

disk in the system, and

that disk’s previous

location has been taken

by a replacement disk

through a rebuild, you

must manually remove

the foreign

configuration flag of

the newly inserted disk.

Previous
configuration(s)
cleared or missing.
Importing
configuration created
on XX/XX XX.XX. Press
any key to continue,
or ’C’ to load the
configuration utility.

The message indicates that

the controller and physical

disks have different

configurations.

You can use the BIOS

Configuration Utility

to clear the foreign

configuration.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 138 Thursday, March 3, 2011 2:14 PM