Storage Controller Features

BBU (Backup

Battery Unit)

Optional

Optional

Yes

Optional,

Transportable

Non-Volatile

Cache

Optional

Optional

No

Optional,

Transportable

Cache Memory 512 MB DDR2 or 1

GB DDR2

512 MB

DDR2 or 1

GB DDR2

512 MB

Integrated

DDR2

512 MB DDR2

or 1 GB DDR2

Cache

Function

Write-Back, Write-

Through, Adaptive

Read Ahead, No-

Read Ahead, Read

Ahead

Write-Back,

Write-

Through,

Adaptive

Read Ahead,

No-Read

Ahead, Read

Ahead

Write-Back,

Write-

Through,

Adaptive

Read Ahead,

No-Read

Ahead, Read

Ahead

Write-Back,

Write-Through,

Adaptive Read

Ahead, No-Read

Ahead, Read

Ahead

Maximum

Number of

Spans per Disk

Group

8

8

2

8

Maximum

Number of

Virtual Disks

per Disk Group

16 virtual disks per

disk group

16 virtual

disks per disk

group

16 virtual

disks per disk

group

16 virtual disks

per disk group

Multiple

Virtual Disks

per Controller

Up to 64 virtual

disks per controller

Up to 64

virtual disks

per controller

Up to 64

virtual disks

per

controller

Up to 64 virtual

disks per

controller

Support for x8

2.0 PCIe Host

Interface

Yes

Yes

Yes, x4 PCIe

2.0 for host

operation

Yes

Online

Capacity

Expansion

Yes

Yes

Yes

Yes

Table 3-1. PERC H700 and H800 Card Comparisons