Dell PowerEdge RAID Controller H700 User Manual

Page 133

Advertising
background image

Troubleshooting

133

All of the disks from
your previous
configuration are
gone. If this is an
unexpected message,
then please power off
your system and check
your cables to ensure
all disks are present.
Press any key to
continue, or 'C' to
load the configuration
utility.

The message indicates that

all configured disks were

removed. If the disks were

not removed, they are no

longer accessible. The SAS

cables for your system

might be improperly

connected.

Check the cable

connections and restart

the system.
If there are no cable

problems, press any key

or <C> to continue.

The following virtual
disks are missing: (x)
If you proceed (or
load the configuration
utility), these
virtual disks will be
removed from your
configuration. If you
wish to use them at a
later time, they will
have to be imported.
If you believe these
virtual disks should
be present, please
power off your system
and check your cables
to ensure all disks
are present. Press any
key to continue, or
'C' to load the
configuration utility.

The message indicates that

some configured disks were

removed. If the disks were

not removed, they are no

longer accessible. The SAS

cables for your system

might be improperly

connected.

Check the cable

connections and restart

the system.
If there are no cable

problems, press any key

or <C> to continue.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 133 Thursday, March 3, 2011 2:14 PM

Advertising