Dell PowerEdge RAID Controller H700 User Manual

Page 49

Advertising
background image

Installing and Configuring Hardware

49

Removing and Installing the PERC H700 Modular

Card in Dell Blade Systems

NOTE:

For more information on removing and installing blade system parts, see

your system’s

Hardware Owner’s Manual or the User’s Guide from the Dell Support

website at support.dell.com.

The storage controller card is located below the disk bays of the Dell Blade

system.
To remove the storage controller card:

1 Remove the Dell Blade system from the Blade system chassis.
2 Remove the system cover of the Blade system.
3 Remove the system board and place it on a stable and flat surface.
4 Determine whether the dirty cache LED on the controller is illuminated.

For location of the LED, see Figure 4-7.
If the LED is illuminated, re-insert the system board, replace the system

cover, reconnect the system to power, turn on the system, and repeat step 1

through step 3. If the LED is not illuminated, continue with the next step.

5 Open the release lever to disconnect the storage controller card edge

connector from the system board connector as illustrated in Figure 4-7.

6 Lift the storage controller card straight up from the system board as

illustrated in Figure 4-7.

PERC7.2_UG.book Page 49 Thursday, March 3, 2011 2:14 PM