Replace Member Errors

Table 9-6 describes issues related to the Replace Member feature.

NOTE:

For more information about the Replace Member features, see "Using

Replace Member and Revertible Hot Spares" on page 35.

Table 9-6. Replace Member Operation Errors

Issue

Corrective Action

The source disk fails

during the Replace

Member operation.

If the source data is available from other disks in the virtual

disk, the rebuild begins automatically on the target disk, using

the data from the other disks.

Target disk fails

If the target disk fails, the Replace Member operation aborts.

Other disks fail

If the target disk fails and the Replace Member operation

aborts but the source data is still available, then the Replace

Member operation continues as Replace Member.

PERC7.2_UG.book Page 147 Thursday, March 3, 2011 2:14 PM