Dell PowerEdge RAID Controller H700 User Manual

Page 140

Advertising
background image

140

Troubleshooting

Some configured disks
have been removed from
your system or are no
longer accessible.
Check your cables and
ensure all disks are
present. Press any key
or ’C’ to continue.

The message indicates that

some configured disks were

removed. If the disks were

not removed, they are no

longer accessible.
The SAS cables for your

system might be

improperly connected.

Check the cable

connections and restart

the system.
If there are no cable

problems, press any key

or <C> to continue.

The battery is
currently discharged
or disconnected.
Verify the connection
and allow 30 minutes
for charging.If the
battery is properly
connected and it has
not returned to
operational state
after 30 minutes of
charging then contact
technical support for
additional assistance.

NOTE:

This message may

appear for controller

without battery, depending

on the virtual disks’ policies.

• The controller

battery is missing or

currently

inaccessible. Contact

Dell Technical

Support if the issue

persist after 30

minutes.

• The controller

battery is completely

discharged and

needs to be charged

for it to become

active. You must first

charge the battery,

then wait for a few

minutes for the

system to detect it.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 140 Thursday, March 3, 2011 2:14 PM