Dell PowerEdge RAID Controller H700 User Manual

Page 89

Advertising
background image

Configuring and Managing RAID

89

9 Use the arrow key to highlight a physical disk and press the spacebar,

<Alt>, or <Enter> to select the disk.

10 Select additional disks, if required.
11 Press <Tab> to move the cursor to the Basic Settings box.
12 Set the virtual disk size in the VD Size field.

The virtual disk size is displayed in GB format.

NOTE:

You can use part of the available disk space to create one virtual disk

and then use the rest of the disk space to create another virtual disk or disks.

13 Press <Tab> to access the VD Size field, and type a virtual disk name.
14 Press <Tab> to move the cursor to Advanced Settings.
15 Press the spacebar to make the settings active so that you can change

them.
An X is displayed beside

Advanced Settings. The settings are the stripe

element size, read policy, and write policy. You can also choose advanced

options such as forcing the cache policy to

Write-Back, initializing the

virtual disk, and configuring a dedicated hot spare.
The defaults parameters are displayed. You can accept the defaults or

change them. For detailed information about the virtual disk parameters,

see "Virtual Disk Parameters and Descriptions" on page 86.

16 Perform the following steps to select the virtual disk parameters:

a

Press <Tab> to move the cursor to the parameters you want to

change.

b

Press the down-arrow key to open the parameters and scroll down the

list of settings.

c

To change the stripe element size, press <Tab> to highlight Stripe

Element Size.

d

Press <Enter> to display the list of stripe element sizes (8 KB, 16 KB,

32 KB, 64 KB, 128 KB, 256 KB, 512 KB, and 1024 KB). Press the

down-arrow key to highlight the desired option and press <Enter>.

The default is

64 KB.

e

If you need to change the read policy, press <Tab> to move the cursor

to

Read Policy.

PERC7.2_UG.book Page 89 Thursday, March 3, 2011 2:14 PM