Dell PowerEdge RAID Controller H700 User Manual

Page 132

Advertising
background image

132

Troubleshooting

Cache data was lost,
but the controller has
recovered. This could
be due to the fact
that your controller
had protected cache
after an unexpected
power loss and your
system was without
power longer than the
battery backup time.
Press any key to
continue or 'C' to
load the configuration
utility.

This message is displayed

under the following

conditions:

• The adapter detects that

the cache in the

controller cache has not

yet been written to the

disk subsystem.

• The controller detects an

Error-Correcting Code

(ECC) error while

performing its cache

checking routine during

initialization.

• The controller discards

the cache rather than

sending it to the disk

subsystem because the

data integrity cannot be

guaranteed.

To resolve this

problem, allow the

battery to charge fully.

If the issue persists, the

battery or adapter

DIMM might be faulty;

contact Dell Technical

Support.

The following virtual
disks have missing
disks: (x). If you
proceed (or load the
configuration
utility), these
virtual disks will be
marked OFFLINE and
will be inaccessible.
Please check your
cables and ensure all
disks are present.
Press any key to
continue, or 'C' to
load the configuration
utility.

The message indicates that

some configured disks were

removed. If the disks were

not removed, they are no

longer accessible. The SAS

cables for your system

might be improperly

connected.

Check the cable

connections and restart

the system.
If there are no cable

problems, press any key

or <C> to continue.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 132 Thursday, March 3, 2011 2:14 PM

Advertising