Installing and Configuring Hardware

63

Transferring a TBBU or TNVC Between PERC

H800 Cards

The TBBU or TNVC provides uninterrupted power supply for up to 48 hours

to a cache memory module. If the controller fails as a result of a power failure,

you can move the TBBU or TNVC to a new controller and recover the data.

The controller that replaces the failed controller should not have any prior

configuration.
Perform the following steps to replace a failed controller with data in the

TBBU:

1 Perform a controlled shutdown on the system in which the PERC H800 is

installed, as well as any attached storage enclosures.

2 Disconnect the system from the electrical outlet and remove the system

cover.

3 Remove the controller that has the TBBU or TNVC.
4 Remove the TBBU or TNVC from the controller.
5 Insert the TBBU or TNVC in the new controller.

For more information on installing the TBBU or TNVC, see "Installing the

TBBU or TNVC on a PERC H800 Adapter" on page 61.

6 Insert the replacement controller in the system.

See the relevant sections on installing controllers under "Installing the

PERC H700 and H800 Adapters" on page 41.

7 Reconnect all external storage enclosures as they were originally connected

and turn on the enclosures.

8 Replace the system cover, re-connect the system to the electrical outlet

and turn on the system.
The controller flushes the cache data to the virtual disks.

PERC7.2_UG.book Page 63 Thursday, March 3, 2011 2:14 PM