Dell PowerEdge RAID Controller H700 User Manual

Page 137

Advertising
background image

Troubleshooting

137

Memory/Battery
problems were
detected. The adapter
has recovered, but
cached data was lost.
Press any key to
continue.

This message occurs under

the following conditions:

• The adapter detects data

in the controller cache

that has not yet been

written to the disk

subsystem.

• The controller detects an

Error-Correcting Code

(ECC) error while

performing its cache

checking routine during

initialization.

• The controller discards

the cache rather than

sending it to the disk

subsystem because the

data integrity cannot be

guaranteed.

• The battery may be

under charged.

Allow the battery to

charge fully to resolve

this problem. If the

issue persists, the

battery or adapter

DIMM might be faulty;

contact Dell Technical

Support.

Firmware is in Fault
State

Contact Dell Technical

Support.

Foreign
configuration(s) found
on adapter. Press any
key to continue, or
’C’ to load the
configuration utility
or ’F’ to import
foreign
configuration(s) and
continue.

When a controller

firmware detects a physical

disk with existing foreign

metadata, it flags the

physical disk as foreign and

generates an alert

indicating that a foreign

disk was detected.

Press <F> at the

prompt to import the

configuration (if all

member disks of the

virtual disk are present)

without loading the

BIOS Configuration

Utility. Or, press <C>

to enter the BIOS

Configuration Utility

and either import or

clear the foreign

configuration.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 137 Thursday, March 3, 2011 2:14 PM