Dell PowerEdge RAID Controller H700 User Manual

Page 136

Advertising
background image

136

Troubleshooting

There are offline or
missing virtual drives
with preserved cache.
Please check the
cables and ensure that
all drives are
present.
Press any key to enter
the configuration
utility.

The controller preserves

the dirty cache from a

virtual disk if the disk

becomes offline or is

deleted because of missing

physical disks.
This preserved dirty cache

is called pinned cache, and

is preserved until you

import the virtual disk, or

discard the cache.

Use the

<Ctrl><R>

utility to import the

virtual disk or discard

the preserved cache.

For the steps used to

manage preserved

cache, see "Managing

Preserved Cache" on

page 96.

x Virtual Disk(s)
Offline
where x is the number of virtual

disks failed

This warning is displayed

when the BIOS detects

virtual disks in the offline

state.

You must check to

determine why the

virtual disks failed and

correct the issue. The

BIOS does not take any

action.

x Virtual Disk(s)
Degraded
where x is the number of virtual

disks degraded

This message is displayed

when the BIOS detects

virtual disks in a degraded

state.

Take corrective

action(s) to make the

virtual disks optimal.

The BIOS does not

take any action.

x Virtual Disk(s)
Partially Degraded

This message is displayed

when the BIOS detects a

single disk failure in a

RAID 6 or RAID 60

configuration.

You must check why

the member disk is not

present to correct the

problem. The BIOS

does not take any

action.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 136 Thursday, March 3, 2011 2:14 PM