Troubleshooting

139

Invalid SAS topology
detected. Please check
your cable
configurations, repair
the problem, and
restart your system.

The SAS cables for your

system are improperly

connected.

Check the cable

connections and restart

the system.

Multibit ECC errors
were detected on the
RAID controller. If
you continue, data
corruption can occur.
Contact technical
support to resolve
this issue. Press 'X'
to continue or else
power off the system,
replace the controller
and reboot.

This error is specific to the

PERC H700 controller.
Multi-bit ECC errors

(MBE) occur in the

memory and can corrupt

cached data and discard it.

CAUTION:

MBE

errors are serious, as
they cause data
corruption and data
loss. In case of MBE
errors, contact Dell
Technical Support.

NOTE:

A similar

message is displayed

when multiple single-bit

ECC errors are detected

on the controller during

bootup.

Multibit ECC errors
were detected on the
RAID controller.The
DIMM on the controller
needs replacement. If
you continue, data
corruption can occur.
Press 'X' to continue
or else power off the
system, replace the
DIMM module, and
reboot. If you have
replaced the DIMM
please press 'X' to
continue.

Multi-bit ECC errors

(MBE) occur in the

memory and can corrupt

cached data and discard it.

CAUTION:

MBE

errors are serious,
as they cause data
corruption and loss.
In case of MBE errors,
contact Dell Technical
Support.

Table 9-1. BIOS Errors and Warnings

(continued)

Error Message

Probable Cause

Corrective Action

PERC7.2_UG.book Page 139 Thursday, March 3, 2011 2:14 PM