Dell PowerEdge RAID Controller H700 User Manual

Page 86

Advertising
background image

86

Configuring and Managing RAID

When you define the virtual disks, you can set the following virtual disk

parameters:

• RAID level
• Stripe element size
• Read policy
• Write policy
• Type of initialization
• Hot spare configuration

NOTE:

The default hard drive cache policy for a virtual disk composed with SAS

hard drives is

disabled and with SATA hard drives is enabled. The Virtual Disk

parameter can not be changed in the BIOS configuration Utility.

Table 6-2 shows the parameters that you can configure when defining

virtual disks.

Table 6-2. Virtual Disk Parameters and Descriptions

Parameter

Description

RAID Level RAID Level specifies whether the virtual disk is RAID 0, 1, 5, 6, 10,

50, or 60. The number of disks, disk capacity, the requirements for

fault tolerance, performance, and capacity should be considered when

selecting the RAID level. For more information, see "Summary of

RAID Levels" on page 17.

Stripe

Element Size

Stripe Element Size specifies the size of the segments written to each

physical disk in a RAID 0, 1, 5, 6, 10, 50, and 60 virtual disk. You can

set the stripe element size to 8 KB, 16 KB, 32 KB, 64 KB, 128 KB,

256 KB, 512 KB, or 1024 KB. The default and recommended stripe

element size is 64 KB.
A larger stripe element size provides better read performance if your

system mostly does sequential reads.

PERC7.2_UG.book Page 86 Thursday, March 3, 2011 2:14 PM