Storage Controller Features

Table 3-2. RAID Level Migration

Source
RAID
Level

Target
RAID
Level

Required
Number of
Physical Disks
(Beginning)

Number of
Physical
Disks (End)

Capacity
Expansion
Possible

Description

RAID 0 RAID 0 1

2 or more

Yes

Increases capacity by

adding disks

RAID 0 RAID 1 1

2

No

Converts

non-redundant

virtual disk into a

mirrored virtual disk

by adding one disk.

RAID 0 RAID 5 1 or more

3 or more

Yes

At least one disk

needs to be added for

distributed parity data.

RAID 0 RAID 6 1 or more

4 or more

Yes

At least two disks need

to be added for dual

distributed parity data.

RAID 1 RAID 0 2

2 or more

Yes

Removes redundancy

while increasing

capacity.

RAID 1 RAID 5 2

3 or more

Yes

Maintains redundancy

while doubling

capacity.

RAID 1 RAID 6 2

4 or more

Yes

Two disks required to

be added for

distributed parity data.

RAID 5 RAID 0 3 or more

3 or more

Yes

Converts to a

non-redundant virtual

disk and reclaims

disk space used for

distributed parity data.

RAID 5 RAID 5 3

4 or more

Yes

Increases capacity by

adding disks

PERC7.2_UG.book Page 32 Thursday, March 3, 2011 2:14 PM