Dell POWEREDGE R515 User Manual

Page 30

Advertising
background image

30

About Your System

E1410 System Fatal

Error
detected.

Specified processor has an

internal error. The error

may or may not have

been caused by

the processor.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 187.

E1414 CPU # temp

exceeding
range.
Check CPU
heatsink.

Specified processor is out

of acceptable

temperature range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting

Processors" on page 174

and "Troubleshooting

System Cooling

Problems" on page 163.

E1418 CPU # not

detected.
Check CPU
is seated
properly.

Specified processor is

missing or bad,

and the system is in an

unsupported

configuration.

Ensure that the specified

processor is properly

installed. See

"Troubleshooting

Processors" on page 174.

E141C Unsupported

CPU config.
Check CPU or
BIOS revision.

Processors are in an

unsupported

configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

E141F CPU # protocol

error. Power
cycle AC.

The system BIOS

has reported a processor

protocol error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 187.

Code

Text

Causes

Corrective Actions

book.book Page 30 Tuesday, August 24, 2010 1:47 PM

Advertising